Dental Research - Implants, Health, Hygiene, Cosmetic, Dentistry

Dental Research Today is a free monthly online journal that collates and summarizes the latest research about Dental, including details on implants, health, hygiene, cosmetic, dentistry.


Dental Research Today

Home

View Latest Issue

Information About Dental

Books on Dental

Advertising in Research Today

View Other Research Today Publications



The impact of prosthetic design on the stability, marginal bone loss, peri-implant sulcus fluid volume, and nitric oxide metabolism of conventionally loaded endosseous dental implants: a 12-month clinical study.

Tözüm TF, Güncü GN, Yamalik N, Turkyilmaz I, Güncü MB

Department of Periodontology, Faculty of Dentistry, Hacettepe University, Ankara, Turkey. ttozum@hacettepe.edu.tr

BACKGROUND: Further clarification of the early and late response of peri-implant tissues to surgical insertion and loading of dental implants and the potential associations among the various implant-related measures are likely to improve the evaluation/monitoring of implant sites. Thus, analyses were made of the volume and nitric oxide (NO) profile of peri-implant sulcus fluid (PISF), implant stability, and marginal bone level in relation to different prosthetic designs. METHODS: Seven totally edentulous subjects and 11 partially edentulous subjects were included. Resonance frequency analysis (RFA), marginal bone level measurements, PISF volume, and spectrophotometrically determined nitrite levels were analyzed comparatively at conventionally loaded (CL) implant sites and at implants with removable prostheses (RP; N = 14) and fixed prostheses (FP; N = 11) for a period of 12 months. RESULTS: At implant sites with RP, PISF volume decreased gradually and its lowest level occurred at the end of the experimental period. The PISF nitrite content increased until 6 months and was followed by a significant decrease at 12 months. Compared to baseline, RFA values exhibited a significant decrease at 1 and 3 months. Marginal bone level was significantly lower at all follow-up visits compared to baseline. More volumetric fluctuations of PISF was noted at implant sites with FP. The PISF nitrite content had decreased, compared to baseline, at 6, 9, and 12 months. A general stability was observed for RFA. The marginal bone loss observed at 6 months was followed by a gain at 12 months. An inverse relationship was noted between RFA values and marginal bone levels. CONCLUSION: The prosthetic design particularly seems to affect the NO metabolism around CL implants, whereas it does not seem to have any impact on the stability of dental implants.

Published 1 January 2008 in J Periodontol, 79(1): 55-63.
Full-text of this article is available online (may require subscription).

Place a permanent text-link or advertisement here for just US$15.

© 2004-2008 Dental Research Today. All Rights Reserved.



Dental Research Today Archive:

Volume 1 (2004)
  Issue 1 (October)
  Issue 2 (November)
  Issue 3 (December)

Volume 2 (2005)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 3 (2006)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 4 (2007)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 5 (2008)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)



Dental Books

Schaum's Outline of Organic Chemistry

Schaum's Outline of Organic Chemistry