Dental Research - Implants, Health, Hygiene, Cosmetic, Dentistry

Dental Research Today is a free monthly online journal that collates and summarizes the latest research about Dental, including details on implants, health, hygiene, cosmetic, dentistry.


Dental Research Today

Home

View Latest Issue

Information About Dental

Books on Dental

Advertising in Research Today

View Other Research Today Publications



Parameters of resonance frequency measurement values: a retrospective study of 385 ITI dental implants.

Karl M, Graef F, Heckmann S, Krafft T

Department of Prosthodontics, University of Erlangen-Nuremberg, Erlangen, Germany.

Objectives: There is no proven clinical tool to evaluate the amount of osseointegration and stability around dental implants. Therefore, the aim of this retrospective clinical study was to evaluate resonance frequency analysis values of 385 ITI solid screw implants. Material and methods: Both at implant placement and after healing, implant stability quotients (ISQs) were determined. For statistical analysis, Pearson's correlation coefficients, Welch's two-sample t-tests and paired samples t-tests were computed at a level of significance of alpha=0.05. Results: ISQ values ranged from 39 to 86 at implant placement and from 35 to 89 after healing, showing a significant increase. The highest ISQ values at both stages were obtained in the posterior mandible (P</=0.002). After healing, ISQ values in the anterior mandible were significantly higher than in the anterior maxilla (P=0.005). Implant length had a significant influence on ISQ in the anterior mandible (P=0) at insertion and in the anterior (P=0.005) and posterior mandible (P=0.036) after healing. Implant diameter and ISQ at insertion correlated in the anterior mandible (P=0.037). After healing, a significant influence was found for all regions, except the posterior maxilla (P=0.795). With the exception of the anterior maxilla (P=0.542), ISQ at placement had a significant influence on ISQ after healing. In the anterior maxilla (P=0.002) and in the posterior mandible (P=0.007), healing time significantly influenced ISQ after healing. Conclusions: It appears that only repeated ISQ measurements of a specific implant have some diagnostic benefit, although the parameters influencing the absolute values still remain unclear.

Published 10 January 2008 in Clin Oral Implants Res, 19(2): 214-8.
Full-text of this article is available online (may require subscription).

Place a permanent text-link or advertisement here for just US$15.

© 2004-2008 Dental Research Today. All Rights Reserved.



Dental Research Today Archive:

Volume 1 (2004)
  Issue 1 (October)
  Issue 2 (November)
  Issue 3 (December)

Volume 2 (2005)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 3 (2006)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 4 (2007)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 5 (2008)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)



Dental Books

Mosby's Review for the NBDE, Part II (Mosby's Review for the Nbde: Part 2 (National Board Dental Examination))

Mosby's Review for the NBDE, Part II (Mosby's Review for the Nbde: Part 2 (National Board Dental Examination))