Dental Research - Implants, Health, Hygiene, Cosmetic, Dentistry

Dental Research Today is a free monthly online journal that collates and summarizes the latest research about Dental, including details on implants, health, hygiene, cosmetic, dentistry.


Dental Research Today

Home

View Latest Issue

Information About Dental

Books on Dental

Advertising in Research Today

View Other Research Today Publications



Clinical study on the primary stability of two dental implant systems with resonance frequency analysis.

Rabel A, Köhler SG, Schmidt-Westhausen AM

Department of Oral Medicine, Dental Radiology and Surgery, Charité Center 3 for Dental Medicine, Campus Benjamin Franklin, Charité-Medical University Berlin, Assmannshauser Strasse 4-6, 14197, Berlin, Germany. annette.rabel@charite.de

Primary stability has a major impact on the long-term success of dental implants. The aim of this study was to investigate the correlation of resonance frequency analysis (RFA) and insertion torque of self-tapping and non-self-tapping implants and their respective differences in primary stability. A group of 263 patients were treated with a total of 602 conically formed dental implants: 408 non-self-tapping Ankylos and 194 self-tapping Camlog. The maximum insertion torque during implant placement was recorded. Resonance frequency, measured as the implant stability quotient (ISQ), was assessed once immediately after insertion and twice 3 months later. Torque values of the non-self-tapping implants were significantly higher than those in the self-tapping group (p = 0.023). RFA did not show differences between the 2 groups (p = 0.956), but a correlation between ISQ values after implantation and 3 months after implant placement was measured (r = 0.712). Within the implant systems, no correlation between insertion torque and resonance frequency values could be determined (r = 0.305). Our study indicates that the ISQ values obtained from different implant systems are not comparable. The RFA does not appear suitable for the evaluation of implant stability when used as a single method. Higher insertion torque of the non-self-tapping implants appeared to confirm higher clinical primary stability.

Published 1 August 2007 in Clin Oral Investig, 11(3): 257-65.
Full-text of this article is available online (may require subscription).

Place a permanent text-link or advertisement here for just US$15.

© 2004-2008 Dental Research Today. All Rights Reserved.



Dental Research Today Archive:

Volume 1 (2004)
  Issue 1 (October)
  Issue 2 (November)
  Issue 3 (December)

Volume 2 (2005)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 3 (2006)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 4 (2007)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 5 (2008)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)



Dental Books

Mosby's Review for the NBDE, Part II (Mosby's Review for the Nbde: Part 2 (National Board Dental Examination))

Mosby's Review for the NBDE, Part II (Mosby's Review for the Nbde: Part 2 (National Board Dental Examination))