Absorbed doses on patients undergoing tomographic exams for pre-surgery planning of dental implants.Zenóbio MA, da Silva TA Centro de Desenvolvimento da Tecnologia Nuclear, Comissão Nacional de Energia Nuclear, Caixa Postal 941, CEP 30123-970 Belo Horizonte, MG, Brazil. The thermoluminescent (TL) dosimetry was used to measure entrance skin absorbed doses at anatomical points close to critical organs of patients undergoing tomographic techniques as part of a pre-surgery planning for dental implants. The dosimetric procedure was applied in 19 patients, and absorbed doses could be measured with a combined uncertainty down to 14%. Results showed that patient doses may be increased by a factor of 20 in the helical computed tomography compared to panoramic and spiral conventional tomographic exams. Published 13 April 2007 in Appl Radiat Isot, 65(6): 708-11.