Dental Research - Implants, Health, Hygiene, Cosmetic, Dentistry

Dental Research Today is a free monthly online journal that collates and summarizes the latest research about Dental, including details on implants, health, hygiene, cosmetic, dentistry.


Dental Research Today

Home

View Latest Issue

Information About Dental

Books on Dental

Advertising in Research Today

View Other Research Today Publications



Long-Term Evaluation of Hollow Screw and Hollow Cylinder Dental Implants: Clinical and Radiographic Results After 10 Years.

Telleman G, Meijer HJ, Raghoebar GM

* Faculty of Medical Sciences, University Medical Center Groningen, Groningen, The Netherlands., † Department of Oral-Maxillofacial Surgery and Maxillofacial Prosthetics, University Medical Center Groningen., ‡ Department of Oral Function and Prosthetic Dentistry, Dental School, Faculty of Medical Sciences, University Medical Center Groningen.

Background: In 1988, an implant manufacturer offered a new dental implant system, with a wide choice of hollow cylinder (HC) and hollow screw (HS) implants. The purpose of this retrospective study of HS and HC implants was to evaluate clinical and radiographic parameters of peri-implant tissue and to analyze surgical and prosthetic aftercare. Methods: A total of 89 HS and 26 HC implants in 38 edentulous patients were available for complete evaluation. The patients were treated with overdentures stabilized by two or four implants. The follow-up period was 10 years. Results: The results of the clinical evaluation showed a mean sulcus probing depth of 3.3 +/- 1.3 mm (range = 2 to 10 mm). The mean radiographic bone loss was 2.2 +/- 2.1 mm (range = 0.1 to 12.2 mm). One implant (HS) was removed during the osseointegration period. Three other implants (two HS and one HC) in three patients had to be removed after 10 years. The survival rate of the HS implant (96.6%) was comparable to the HC implant (96.1%). The success rate of the HS implant (93.3%) was slightly more favorable compared to the HC implant (88.5%). The HS and HC implants met the Albrektsson criteria of success. Conclusions: HS and HC implants provide a stable base for long-term support of a mandibular overdenture. Furthermore, it is important to monitor peri-implant bone level by taking annual radiographs and measuring probing depth, especially after prolonged service.

Published 7 February 2006 in J Periodontol, 77(2): 203-210.
Full-text of this article is available online (may require subscription).

Place a permanent text-link or advertisement here for just US$15.

© 2004-2008 Dental Research Today. All Rights Reserved.



Dental Research Today Archive:

Volume 1 (2004)
  Issue 1 (October)
  Issue 2 (November)
  Issue 3 (December)

Volume 2 (2005)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 3 (2006)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 4 (2007)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 5 (2008)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)



Dental Books

Mosby's Review for the NBDE, Part II (Mosby's Review for the Nbde: Part 2 (National Board Dental Examination))

Mosby's Review for the NBDE, Part II (Mosby's Review for the Nbde: Part 2 (National Board Dental Examination))